Skip to content
English
  • There are no suggestions because the search field is empty.

Firmware Update - FLIP Timeout Error

Resolving FLIP timeout errors during He/O2 or SOLO Analyzer update

Possible causes:

  • Not holding the ON/OFF button during whole update
  • Driver issues on computer
  • USB cable or HUB issues
  • Incorrect update procedure
  • MCU type selection not matching the HW revision

Step-by-step troubleshooting:

  • During the whole firmware update using the FLIP, it is essential to hold the ON/OFF button on the Analyzer
  • Double-check the MCU selection in FLIP
    • Select AT89C51ED2 for HW rev. 1.0 to 2.3
    • Select AT89C51RE2 for HW rev. 2.4 and up
  • Install/reinstall Flip drivers
  • Try shorter USB cable (under 1.5 meter)
  • Restart computer and analyzer
  • Follow the official firmware update guide for He/O2 or SOLO.

When to contact service: If FLIP timeout persists across multiple computers.